Skip to content

Latest commit

 

History

History
259 lines (192 loc) · 7.11 KB

Set-IntersightFabricServerRole.md

File metadata and controls

259 lines (192 loc) · 7.11 KB
external help file Module Name online version schema
Intersight.PowerShell.dll-Help.xml
Intersight.PowerShell
2.0.0

Set-IntersightFabricServerRole

SYNOPSIS

Fill in the Synopsis

SYNTAX


Set-IntersightFabricServerRole [-AdditionalProperties< System.Collections.Generic.Dictionary`2[string,object]>][-AggregatePortId< long>][-AutoNegotiationDisabled< bool>][-Fec< FabricServerRole.FecEnum>][[-Moid]< string>][-PortId< long>][-PortPolicy< FabricPortPolicyRelationship>][-PreferredDeviceId< long>][-PreferredDeviceType< FabricServerRole.PreferredDeviceTypeEnum>][-SlotId< long>][-Tags< System.Collections.Generic.List`1[MoTag]>][-Json< SwitchParameter>][-WithHttpInfo< SwitchParameter>]

DESCRIPTION

Update a 'FabricServerRole' resource.

PARAMETERS

-AdditionalProperties

Type: System.Collections.Generic.Dictionary`2[string,object]
Parameter Sets: (All)
Aliases:

Required: false
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: False

-AggregatePortId

Breakout port Identifier of the Switch Interface.\nWhen a port is not configured as a breakout port, the aggregatePortId is set to 0, and unused.\nWhen a port is configured as a breakout port, the 'aggregatePortId' port number as labeled on the equipment,\ne.g. the id of the port on the switch.

Type: long
Parameter Sets: (All)
Aliases:

Required: false
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: False

-AutoNegotiationDisabled

Auto negotiation configuration for server port. This configuration is required only for FEX Model N9K-C93180YC-FX3 connected with 100G speed port on UCS-FI-6536 and should be set as True.

Type: bool
Parameter Sets: (All)
Aliases:

Required: false
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: False

-Fec

Forward error correction configuration for server port. This configuration is required only for FEX Model N9K-C93180YC-FX3 connected with 25G speed ports on UCS-FI-6454/UCS-FI-64108 and should be set as Cl74.\n* Auto - Forward error correction option 'Auto'.\n* Cl91 - Forward error correction option 'cl91'.\n* Cl74 - Forward error correction option 'cl74'.

Type: FabricServerRole.FecEnum
Parameter Sets: (All)
Aliases:

Required: false
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: False

-Moid

The unique identifier of this Managed Object instance.

Type: string
Parameter Sets: (All)
Aliases:

Required: true
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: False

-PortId

Port Identifier of the Switch/FEX/Chassis Interface.\nWhen a port is not configured as a breakout port, the portId is the port number as labeled on the equipment,\ne.g. the id of the port on the switch, FEX or chassis.\nWhen a port is configured as a breakout port, the 'portId' represents the port id on the fanout side of the breakout cable.

Type: long
Parameter Sets: (All)
Aliases:

Required: false
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: False

-PortPolicy

A reference to a fabricPortPolicy resource.\nWhen the $expand query parameter is specified, the referenced resource is returned inline.

Note:- To get the relationship object pass the MO to the cmdlet Get-IntersightMoMoRef or use the cmdlet Initialize-IntersightMoMoRef.

Type: FabricPortPolicyRelationship
Parameter Sets: (All)
Aliases:

Required: false
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: False

-PreferredDeviceId

Preferred device ID to be configured by user for the connected device. This ID must be specified together with the 'PreferredDeviceType' property. This ID will only takes effect if the actual connected device matches the 'PreferredDeviceType'. If the preferred ID is not available, the ID is automatically allocated and assigned by the system. If different preferred IDs are specified for the ports connected to the same device, only the preferred ID (if specified) of the port that is discovered first will be considered.

Type: long
Parameter Sets: (All)
Aliases:

Required: false
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: False

-PreferredDeviceType

Device type for which preferred ID to be configured. If the actual connected device does not match the specified device type, the system ignores the 'PreferredDeviceId' property.\n* Auto - Preferred Id will be ignored if specified with this type.\n* RackServer - Connected device type is Rack Unit Server.\n* Chassis - Connected device type is Chassis.

Type: FabricServerRole.PreferredDeviceTypeEnum
Parameter Sets: (All)
Aliases:

Required: false
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: False

-SlotId

Slot Identifier of the Switch/FEX/Chassis Interface.

Type: long
Parameter Sets: (All)
Aliases:

Required: false
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: False

-Tags

Note :- Use Initialize-IntersightMoTag to create the object of complex type MoTag

Type: System.Collections.Generic.List`1[MoTag]
Parameter Sets: (All)
Aliases:

Required: false
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: False

-Json

Returns the json payload received in response.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: false
Position: Named
Default value: None
Accept pipeline input: True False
Accept wildcard characters: False

-WithHttpInfo

Returns the HTTP response with headers and content.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: false
Position: Named
Default value: None
Accept pipeline input: True False
Accept wildcard characters: False

CommonParameters

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

EXAMPLES

Example 1

PS C:\> Set-IntersightFabricServerRole

{ Add example description here }

INPUTS

System.Int32

System.String

OUTPUTS

TestModule.FavoriteStuff

NOTES

RELATED LINKS

Get-IntersightFabricServerRole

Initialize-IntersightMoVersionContext

New-IntersightFabricServerRole

Remove-IntersightFabricServerRole