You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I have read the source code, I think it is due to the ToBaudConstant method in bindings-cpp/src/serialport_unix.cpp. It will convert the baudrate passed by user. For baudrate higher than 230400, it will convert to -1 on MacOS.
I have also tested on windows, no such issue.
Additional information
No response
The text was updated successfully, but these errors were encountered:
SerialPort Version
11.x.x
Node Version
v14.18.0
Electron Version
No response
Platform
Darwin xxx 21.6.0 Darwin Kernel Version 21.6.0: Thu Mar 9 20:08:59 PST 2023; root:xnu-8020.240.18.700.8~1/RELEASE_X86_64 x86_64
Architecture
No response
Hardware or chipset of serialport
No response
What steps will reproduce the bug?
What happens?
Received error in callback, the detailed information is:
Error: Error: Invalid argument calling ioctl(.., IOSSIOSPEED, -1 )
What should have happened?
I have read the source code, I think it is due to the ToBaudConstant method in bindings-cpp/src/serialport_unix.cpp. It will convert the baudrate passed by user. For baudrate higher than 230400, it will convert to -1 on MacOS.
I have also tested on windows, no such issue.
Additional information
No response