umati showcase information model for Flat Glass Processing

In the following the umati showcase describes the additional information on top of the OPC 40301 UA for Flat Glass Processing companion specification.

The following describes the umati showcase information model for Flat Glass Processing.

For participants that are familiar with the information model, we have included comments and descriptions about changes between the release candidate information model and the showcase information model.

All participants not familiar with the release candidate information model do not need to review these changes in detail but rather follow the described model and refer to the provided xml Nodeset files and UA modeler project.

NodeSets for the showcase

Normative NodeSet hosted by the OPC Foundation

General information valid for the umati showcase demonstration

DISCLAIMER For all applications the OPC UA server is to be configured without predefined NodeIDs for the instances. Clients will need to browse Instances or translate BrowsePaths find the NodeID for accessing the address space and available instances.

Identification data

The identification for machine tools are inherited from the Machinery companion specification. To fill the demo dashboard machine page with the most content the variables marked with a strong mandatory should be provided if you like to look the machine identification nicely.

Attribute Value
BrowseName MachineIdentificationType
IsAbstract False
Description Contains information about the identification and nameplate of a machine
References NodeClass BrowseName DataType TypeDefinition Other
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node.
0:HasProperty Variable 0:DefaultInstanceBrowseName 0:QualifiedName 0:PropertyType
0:HasInterface ObjectType IMachineVendorNameplateType
0:HasInterface ObjectType IMachineTagNameplateType
Applied from IMachineVendorNameplateType
0:HasProperty Variable 2:ProductInstanceUri 0:String 0:PropertyType M, RO
0:HasProperty Variable 2:Manufacturer 0:LocalizedText 0:PropertyType M, RO
0:HasProperty Variable 2:ManufacturerUri 0:String 0:PropertyType O, RO
0:HasProperty Variable 2:Model 0:LocalizedText 0:PropertyType M, RO
0:HasProperty Variable 2:ProductCode 0:String 0:PropertyType M, RO
0:HasProperty Variable 2:HardwareRevision 0:String 0:PropertyType O, RO
0:HasProperty Variable 2:SoftwareRevision 0:String 0:PropertyType M, RO
0:HasProperty Variable 2:DeviceClass 0:String 0:PropertyType M, RO
0:HasProperty Variable 2:SerialNumber 0:String 0:PropertyType M, RO
0:HasProperty Variable YearOfConstruction UInt16 0:PropertyType M, RO
0:HasProperty Variable MonthOfConstruction Byte 0:PropertyType O, RO
0:HasProperty Variable InitialOperationDate DateTime 0:PropertyType O, RO
Applied from IMachineTagNameplateType
0:HasProperty Variable 2:AssetId 0:String 0:PropertyType O, RW
0:HasProperty Variable 2:ComponentName 0:LocalizedText 0:PropertyType O, RW
0:HasProperty Variable Location 0:String 0:PropertyType M, RW

Special requirements for correct location of the machine icon on the dashboard

The instance Location property is evaluated according to the special requirements detailed here to place a map icon for the machine.

FAIR Shortnames

Fair shortnames are defined here.

Adaption of the provided information models for your purpose

  • The provided NodeSet contains the address space with the ObjectTypes, VariableTypes and DataTypes of the Flat Glass Processing companion specificaion and must not be changed.

  • Change the URI of the instance namespace (optional, but recommended)

    http://www.<MANUFACTURERDOMAIN>/example

  • The rules for creating a URI can be found online. Please follow this link. In the case of a URL as a URI, it is not necessary that the site actually exists, it only identifies the machine uniquely. In order to simplify debugging it is recommended to choose a URI which allows an identification of the machine also for third persons, e.g. by including the company name.

  • The machine will get a unique NamespaceURI after being integrated to the datahub by addition of a suffix to ensure unique namespaces.

Value mapping between OPC UA companion specification and umati.app Flat Glass Processing

Flat Glass Processing - Overview

Overview

Flat Glass Processing - Identification

Identification

Flat Glass Processing - Jobs

Jobs