Skip to content

jlopez77/DeyeInverter

Repository files navigation

DeyeInverter

Small utility to read data from DEYE Inverters through the Solarman Datalogger. Works with S/N 17*

Tests indicate that the full ModBus is available through the TCP connection. Probably this can lead to modifying Inverter Configuration via TCP calls.

Thanks to @fjcarretero https://github.com/fjcarretero for his incredible support on understanding the data from and to the datalogger. Thanks to @xtheone https://github.com/XtheOne for his original V4 reader that was an inspiration (and I borrowed some code).

Configuration

Edit the config.cfg and enter the following data:

[DeyeInverter]
inverter_ip=192.168.X.XXX
inverter_port=8899
inverter_sn=17XXXXXXXX
installed_power=XXXXX #power in Watts e.g. for 4.5kW write 4500
mqtt=1  # set to 1 for MQTT output, 0 for JSON output.
mqtt_server=192.168.X.X
mqtt_port=1883
mqtt_topic=XXXXXXXXXXXX
mqtt_username=
mqtt_passwd=

Run

{"Running Status()":2,
"Total Grid Produciton(kwh)":829.5,
"Total Grid Produciton(kwh)":0.0,
"Daily Energy Bought(kwh)":0.0,
"Daily Energy Sold(kwh)":15.0,
"Total Energy Bought(kwh)":21.900000000000002,
"Total Energy Bought(kwh)":0.0,
"Total Energy Sold(kwh)":1103.4,
"Total Energy Sold(kwh)":0.0,
"Daily Load Consumption(KWH)":1.2000000000000002,
"Total Load Consumption(KWH)":365.3,
"Total Load Consumption(KWH)":0.0,
"DC Temperature(℃)":149.5,
"AC Temperature(℃)":152.1,
"Total Production(KWH)":1517.4,
"Total Production(KWH)":0.0,
"Alert()":0,
"Alert()":0,
"Alert()":0,
"Alert()":0,
"Alert()":0,
"Alert()":0,
"Daily Production(KWH)":16.900000000000002,
"PV1 Voltage(V)":342.20000000000005,
"PV1 Current(A)":7.800000000000001,
"PV2 Voltage(V)":8.5,
"PV2 Current(A)":0.0,
"Grid Voltage L1(V)":241.3,
"Grid Voltage L2(V)":0.0,
"Load Voltage(V)":242.9,
"Current L1(A)":10.51,
"Current L2(A)":0.0,
"Micro-inverter Power(W)":0,
"Gen-connected Status()":0,
"Gen Power(W)":0,
"Internal CT L1 Power(W)":-2325,
"Internal CT L2  Power(W)":0,
"Grid Status()":-2365,
"Total Gird Power(W)":-2365,
"External CT L1 Power(W)":-2365,
"External CT L2 Power(W)":0,
"Inverter L1 Power(W)":2558,
"Inverter L2 Power(W)":0,
"Total Power(W)":2558,
"Load L1 Power(W)":193,
"Load L2 Power(W)":0,
"Total Load Power(W)":193,
"Battery Temperature(℃)":125.0,
"Battery Voltage(V)":10.14,
"Battery SOC(%)":0,
"PV1 Power(W)":2619,
"PV2 Power(W)":0,
"Battery Status()":0,
"Battery Power(W)":0,
"Battery Current(A)":-0.01,
"Grid-connected Status()":1,
"SmartLoad Enable Status()":16}

Known Issues

The inverter is not fast enough to answer, you can get timeouts if you query it too often.

Contrib

Python is not my strongest suite, feel free to suggest, rewrite or add whatever you feel is necessary.

Home Assistant support

The folder deye_logger contains a Homeassistant add-on. Reference the README.md file in that folder more information.

About

Small utility to read data from DEYE Inverters (and clones)

Topics

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published